Is 3D SVR MRI the Key to Declassifying Fetal Optic Nerve?


In Juang et al.’s retrospective study, all fetal MRI examinations performed at Phoenix Children’s Hospital between January 1, 2020 and August 1, 2022 were reviewed to find those with sufficient quality to reconstruct a 3D SVR image. First, a medical student reader examined the unprocessed fetal brain MRI—either from balanced turbo-field-echo or T2-weighted single-shot fast spin echo (T2 SSFSE) sequences—attempting FOP measurements where feasible.

Then, 3D SVR reconstructions of fetal brain images were performed using a minimum of six T2 SSFSE imaging sequences. With that same reader next examining the reconstructed imaging and recording FOP measurements, two pediatric neuroradiologists with nearly a decade of experience read all FOP measurements. And to estimate the relationship between FOP measurements of normal fetuses and gestational age, nomograms were generated accordingly.

Ultimately, out of 70 fetal MRI scans selected for this ARRS Annual Meeting Summa Cum Laude award-winning Online Poster, FOP was visualized in 9 cases in unprocessed fetal MRIs, compared to 55 cases in 3D SVR images. Furthermore, among the 55 3D SVR cases, pre-chiasmatic optic nerve width was successfully measured bilaterally in 53 cases, optic chiasm width in all 56 cases, and bilateral optic tract width in 30 cases.

Advertisement


Specifically, a linear regression fit estimated the relationship between optic chiasm width (OCW) in millimeters in normal fetuses and gestational age (GA) in weeks as OCW = 0.11 × GA+2.0 (R^2 = 0.30); similarly, the relationship between pre-chiasmatic (PC) optic nerve width and GA was estimated as PC = 0.04 × GA +0.24 (R^2 = 0.34).

Source: Eurekalert



Source link